For an engineer who is new to designing multi-storey buildings it is important that they follow a logical sequence through the various stages of the design process. Six steps that define this sequence are described below. Rules of thumb are included within each step to help the designer quickly and efficiently arrive at a solution that is sensible for a given set of constraints. In addition, it is important for the designer to understand some overarching principles of good design so that the result is not only sensible but is also good.
If you are looking for more details, kindly visit our website.
Stages of a project
The stages of a construction project are presented in ISE publication Structural design the engineers role[1] which may be broadly summarised as follows:
Many of these stages include aspects of engineering design. A characteristic of steel framed construction is that the constituent parts of the structure are manufactured off-site, with all the quality and speed-on-site benefits that are associated with such a form of construction. An implication of this, however, is that the design must be substantially complete before steelwork fabrication can begin. It is therefore important that the designer follows a logical sequence, as going back and revisiting earlier design decisions, once other parties involved have moved on to designing other parts of the building or manufacturing components, can be disproportionately expensive.
Basic principles of good design
Some basic choices may have a significant impact on the ease, time and cost of both the fabrication and construction of a steel framed multi-storey building. Keeping fabrication and construction in mind from the start will lead to the best possible solution. The designer should also avoid over-specification, a trivial example being that corrosion protection is not needed when steel components are used in many internal environments.
Keep it simple and familiar
Steel is a versatile material. It can be used for single storey buildings, for which its efficiency has helped it reach over 95% market share, and it can be used for high rise buildings, for which its high strength to weight ratio makes it the only practical choice. Because of the different ways that steel beams can be configured, steel structures can be used to create flooring solutions that are competitive for spans ranging from 6 m to over 20 m. When choosing between these steel solutions, a basic principle for the designer should always be to keep it simple, and use solutions that are familiar not only to him/her as the designer, but will also be familiar to the fabricator and erector. Complexity and lack of familiarity are more likely to result in misunderstandings or mistakes, and may cost more. Exotic solutions should only be used for exotic applications that justify the use of non-standard and unfamiliar solutions because of the other attributes they bring.
Lowest embodied carbon
Whilst there may be some arguments for having a heavier section, over design and over specification should be avoided. The lowest embodied carbon solution should be chosen whilst considering any robustness, temporary works and fire protection requirements. However, care should be taken as the lowest weight solutions may require local reinforcement.
Standardise
Beam to beam connections - Typical partial depth end plate connection between beams
Closely related to familiarity is standardisation. Although the use of standard member sizes is less important than it used to be, given modern ways of modelling and fabrication, there may still be benefit in reducing the number of different member sizes used on a project. This desire for standardisation goes right down to the steel grade and bolt grades and sizes.
Rolled sections should only be specified in grade S355 steel (or higher grade) steel to ensure availability as well as performance benefits. However, for the fittings (plates used for connections etc.), many steelwork contractors prefer grade S275 steel. Again, a key is to avoid mixing steel grades for components that look otherwise identical as this facilitates quality assurance.
One of the main areas where standardisation is beneficial is the joints (or connections as they are traditionally termed in the UK). The use of standard joints means the design process is greatly simplified, for example because resistances are tabulated or software can be used more effectively, and the detailing will be acceptable to those who will fabricate and erect the steelwork standardisation, simplicity, familiarity.
Standard beam-to-column and beam-to-beam simple joints adopt one of the three following options, each with its own particular advantages and areas where it is less appropriate:
Double angle cleats are no longer commonly used for simple connections in the UK.
Standard joints use standard bolts (typically either M20 or M24 Property Class 8.8), and standard plate thicknesses (10, 12 and 15 mm). Welded joints are normally restricted to the fabrication shop, where conditions are much more suitable. Bolted site joints have the additional benefit of facilitating deconstruction.
When detailing joints some other rules of thumb should be followed:
Pay attention to interfaces
The steel frame itself represents only a small part of the overall cost of a building. However, how the frame is designed and detailed may affect the cost of more expensive components it interfaces with. Interfaces is an area where attention to detail can pay real dividends. There are basically two things to consider at an interface:
When different tolerances need to be accommodated it is much better to achieve this through design and detailing than through remedial work on site. So, for example, when steelwork is to be connected to a concrete core, the use of brackets that permit adjustments in two orthogonal directions (through the use of slotted holes) should be envisaged from the outset.
The design process
Six steps are chosen to split the design process into a logical sequence from early scheme design consideration through to detailed design. They cover:
Building specific requirements
The basic building shape will normally be chosen, or at least heavily influenced, by other members of the design team. It will often be dictated by site restrictions, be they physical or regulatory such as planning restrictions. Before developing this basic shape into a design the engineer should make sure he/she is aware of any project specific requirements.
Ground conditions may have a fundamental impact on a number of decisions:
It is also worth noting that steel piled foundations (with their number minimised by adopting a long spanning structural frame solution), can easily be removed at the end of building life, avoiding the knock-on effects often found on redevelopment sites and improving the overall sustainability of the solution.
Other aspects of a given site that may favour a certain building frame solution include any access and height restrictions. In a congested city centre using prefabricated elements may be attractive, to minimise the number of vehicles needed to bring all the materials to site. If access routes are of limited width, or have certain other particular characteristics, these may impact on the size of components, or sub structures, that can be delivered. If there is a restriction on the overall height of a building it may favour the use of shallow floor solutions, even though their spanning ability is less than other steel options, to minimise floor depth and therefore maximise the number of floors (and lettable floor space) that can be accommodated within the overall height.
Congested city centre location
In addition to any peculiarities of a given site, there may be particular requirements for the building and its use. For some types of use there are specific, published requirements, such as the Building Bulletins for Education buildings and the Health Technical Memoranda for Healthcare buildings. Particular requirements may include:
If the building is speculative the developer may want maximum flexibility for floor use, services etc. BS EN -1-1 [2] presents minimum imposed floor loads for different building uses. For offices, the imposed loading is typically 3 kN/m2. In addition, up to 1 kN/m2 may be added to cover loading from movable partitions. For storage areas, a higher value of 5 kN/m2 may be used. Often, an imposed load of 5 kN/m2 is specified in speculative offices to allow for a wide range of client uses. As well as the self-weight of the floors, an additional load of 0.7 kN/m2 should be considered for raised floors, ceilings and building services equipment.
Number of floors
To achieve maximum lettable floor space the design should balance the number of floors against floor-to-floor height, paying attention to the intended building use.
The target floor to floor height is based on a floor to ceiling height of 2.5 m to 2.7 m for speculative offices, or 3 m for more prestige applications, plus the floor depth including services. The following target floor to floor depths as shown in the table below should be considered at the concept design stage:
Typical floor-to-floor heights Prestige office 4 - 4.2 m Speculative office 3.6 - 4.0 m Renovation project 3.5 - 3.9 m
Shallow floor systems can be helpful for a designer trying to achieve the right balance. Although they tend to have a higher cost per unit area, the reduced floor depth may provide the designer with:
The weight and cost of a structural frame per unit of floor area (gross internal area) increases with height, because the wind loading increases nonlinearly with height and this has a significant impact on the design of the frame. The increasing cost per square metre is shown for a range of building heights in the cost table below.
Notes:
Stability system
The resistance of a steel frame against horizontal loading can be achieved in a number of ways. The most appropriate choice depends on the scale of building:
It is also possible to provide lateral stability by using a continuous frame one where there is moment continuity between the beams and columns to limit the sway of the frame. However, whilst such a solution would enable, for example, full glazed walls, the connection detailing will be significantly more onerous, as will be the design. Unless there are specific building requirements that cannot be satisfied using an alternative, such a solution will be a disproportionately expensive way of assuring frame stability.
Whatever assures the stability of a frame needs to be able to resist lateral loads applied in two directions, plus a torque. In a braced frame building, the resistance to horizontal forces is provided by two orthogonal bracing systems:
Vertical bracing (in vertical planes between lines of columns) provides load paths to transfer horizontal forces to ground level and provide a stiff resistance against overall sway. As a minimum, three vertical planes of bracing are needed (at least one plane in each orthogonal direction), to provide resistance in both directions in plan and to provide resistance to torsion about a vertical axis. In practice, more than three are usually provided, for example in the locations shown diagrammatically in the figure right.
At each floor level, bracing in a horizontal plane, (generally provided by floor plate action), provides a load path to transfer the horizontal forces (mainly from the perimeter columns, due to wind pressure on the cladding) to the planes of vertical bracing.
At roof level, a truss wind girder may be used to provide a horizontal bracing system, if there is no slab. See figure left.
Step 2: Choice of grids
Having recognised any building specific requirements, decided on the most appropriate number of floors and, in general terms, how the frame will be stabilised against horizontal loading, the designer should start to consider in more detail how the frame will be laid out. The structural grid is defined principally by a regular spacing of columns, with the primary beams spanning between columns, secondary beams spanning between the primary beams, and floor slabs spanning between the secondary beams. Wherever possible the beams are laid out in an orthogonal arrangement to provide rectangular floor plates as this arrangement enables simple orthogonal connection details between beams and columns to be adopted.
Floor grids define the spacing of the columns in orthogonal directions, which are influenced by:
Beam spans typically fall into the range of 6 m to 16 m, with over 12 m spans being very common on commercial office schemes. Slabs typically span between 3 m and 6 m. The table below shows typical spans for various commonly used floor systems.
Typical spans for various building floor systems
Although opting for a long span solution will increase internal flexibility and maximise the lettable floor space, it should be recognised that spanning ability is only one of the attributes of a given flooring solution. They are also differentiated in terms of fabrication cost, ease of erection, ease of service integration, cost of fire protection, required structural depth for a given span. A designer should decide on the best overall compromise for a given application, remembering the basic mantra of standardisation, simplicity, familiarity. The table shows the relative merits for common floor systems in multi-storey buildings.
For a building where horizontal services are to be accommodated and integrated within the structural floor depth, deep primary beams with holes in their webs (to allow the services to pass through), combined with shallow and therefore short spanning secondary beams is a common choice. Alternatively one may use long secondary and short primary beams, chosen so they are all the same depth.
Two of the more common composite floor systems are shown below. The benefits of composite slab floors using downstand beams, shallow floors including precast slabs, together with the choice of long span beams should be considered holistically and in the context of the specific project under development.
Conventional "downstand" beam
Integrated beam with deep decking
A broad statement taken from the British Council for Offices (BCO) Guide to Specification[3] and SCI P365 states that office buildings with columns at 7.5 to 9 m centres tend to be most economical. More specifically, cost comparison studies have shown that for 3 to 4 storey buildings a composite beam and slab option is likely to be the most economical where the optimum grid size for this type of floor system is typically 7.5 m x 9.0 m. For a typical 8 storey city centre office building, cellular beams and composite slabs were shown to be the most economical. For this size of building a typical optimum grid size of 7.5 m x 15.0 m could be most appropriate.
Step 3: Preliminary sizing
Once the grids are established it is possible to estimate preliminary sizes of the beams using some rules of thumb for span to depth ratios.
An estimation of the preliminary sizes of the beams using some rules of thumb for span to depth ratios for the floor systems mentioned above is presented in the table.
Span to depth ratios for different beam solutions Non-composite primary beams Floor = span/20Long span solutions tend to be shallower,
up to span/20
The slabs that span between downstand beams are typically 130 to 150 mm deep, using C30/37 or LC30/33 concrete. When shallow floor solutions are used the structural floor depth, including the integrated beams, is typically 300 to 400 mm. Typical structural depths (floor to ceiling) are shown in the table.
Columns
Yunsheng supply professional and honest service.
Explore more:The columns in braced frame multi-storey buildings are usually hot rolled UC sections. Rectangular or circular hollow sections can also be used but connections become more complex than when an open cross section is adopted. Typical section sizes for UC columns are given in the table below. The columns are normally continuous over 2 or 3 storeys and the beams discontinuous where they meet the columns.
Typical column sizes for small and medium span composite floors Number of floors supported by column section Universal Column (UC) serial size 1 152 2 - 4 203 3 - 8 254 5 - 12 305 10 - 40 356
Note that small and medium span composite floors generally result in the same serial size for the columns, but the column weight will be greater for the medium spans.
Bracing
Braced frame multi-storey building using X bracing
Steel works well in tension, but only works well in compression if buckling is prevented. So when the bracing is configured so that it only needs to resist tension (when X-bracing is present within a bay, one of the members will be in tension when the wind blows one way, and the other in tension when it blows in the opposite direction) it is possible to use cross-flats (flat steel plates as members). If the bracing must work in compression for example, hollow sections may be used.
There are other criteria to consider when choosing the form of bracing, beyond just structural efficiency. Cross-flats may be useful because they can be hidden within a wall cavity. K-bracing (rather than X bracing) leaves room for doorways, although it needs to be detailed so that it doesnt pick up vertical loads from the floors (for which it has not been designed).
Weight of the steel structure
Preliminary sizing considerations should result in a weight of steel similar to that given in the table below. However, there may be project specific considerations which could affect the values given in the table which are based on generalised situations.
Approximate steel quantities Form of Building Approximate steel quantities(kg/m² floor area)
Beams Columns Bracing Total 3 or 4 storey building of rectangular form 2530 810 23 3540 68 storey building of rectangular form 2530 1215 35 4050 810 storey building with long spans 3540 1215 35 5060 20 storey building with long spans and a concrete core 4050 1013 12 5065
Step 4: Analysis
Determining the loads
Before the frame can be analysed and the structural members designed, it is necessary to determine the magnitude of loads and other actions such as thermal movements, which may result in stresses in the structure. The main load types are the self-weight of the structure (and non-structural components), imposed floor loadings, environmental loading including wind and snow, and induced additional loads caused by frame imperfections and sway.
Typical load magnitudes used in building design Loading type Area loading (kN/m2) Permanent loads Steelwork 0.35 0.7 Composite slabs 1.9 3.0 Precast slabs 3.0 4.5 Partitions 1.0 Services 0.25 Ceiling 0.1 Imposed loads Roof 0.6 Floors 2.5 5.0 Wind loads 0.8 1.5 Snow loads 0.6
The structure will be subject to a number of realistic combinations of these load types (they wont all be at their maximum values simultaneously), considering a Limit State Design philosophy where the frame and its members are designed to satisfy different ultimate and serviceability limit states. The combinations, and different limit states, are defined in the relevant Eurocodes.
Determining the internal moments and forces
Once the loads and preliminary member sizes have been identified, the structural analysis can be carried out. This process results in calculation of the internal moments and forces the frame members must be able to resist (against which the preliminary sizes can be checked and the design refined).
The vast majority of steel frames are designed as simple. This means that the beams and columns are assumed to behave as disconnected members (there is no moment continuity between them). A simple frame does not in itself offer stability against lateral loads. Bracing, or a core, typically fulfils this purpose. Assuming simple construction offers a number of benefits and results in certain characteristics of the frame:
If, as an alternative to simple construction, a continuous frame is chosen:
Step 5: Element design
Having determined the moments and forces in the frame members and joints it is possible to move on to detailed design. As noted above, when a frame is continuous it may be necessary to undertake some iteration because the size of the members affects the moments and forces that are attracted to themselves and their neighbours.
Steel member design is based on the requirements given in BS EN -1-1[4]. Composite member design is based on those given in BS EN -1-1[5]. The overall process in steel member design for the ultimate limit state (ULS) involves:
Additionally, members should be designed for any relevant serviceability limit states (SLS), commonly these relate to deformations (deflections), and response to dynamic loading. For most multi-storey commercial buildings, straightforward steel construction will meet the required vibration performance criteria without modification. For more vibration sensitive applications, such as hospital operating theatre floors, steels advantages can be captured with additional stiffening applied to the steel frame if required. Long-span applications, for which steel is the only option, have been found to offer very good vibration damping, despite common preconceptions that damping of composite floors is lower than that of concrete structures. The greater mass of the long-span sections which participate in any motion reduces the magnitude of the vibration response.
Member design is often completed using software, or by reference to the resistance tables in the 'Blue Book' (SCI P363). An extract from the Blue Book presenting the buckling resistance moment for UBs is shown below.
The frame designer must remember to consider the various stages of construction as well as the building in its final state, and the various ULS and SLS checks related to each. Designing the structure to be strong and stiff (and potentially ductile) enough to satisfy the different loading and partial completion scenarios will avoid the need for potentially difficult and costly temporary works.
Step 6: Other checks
In addition to checking the frame members for gravity, imposed and wind loads, some other verifications must also be made as they could affect the final size of the members and joints. These other checks include, but are not restricted to, checking for sway sensitivity, fire performance, robustness and acoustics performance.
Sway sensitivity
Even simple braced frames must be checked for sway sensitivity, as bracing would only prevent all sway if it were infinitely stiff (which clearly nothing is). If the frame proves to be sway sensitive, options (the viability of which will depend on the given building) to design for this sensitivity include:
In the braced frame shown in the figure, the bracing extends due to axial tension, allowing the frame to move laterally, and producing an inclination in the columns, as shown. As the columns are now inclined, additional horizontal components of force must be resisted by the structure.
The horizontal components of the forces in the columns are proportional to the vertical loads, which demonstrates that frame stability is linked to vertical loads.
BS EN -1-1[4], 5.3.2 states that, for frames that are sensitive to buckling, two types of imperfection should be considered:
Fire
One of the limit states that a designer must consider is fire. Steel loses strength as it is heated (it will have lost approximately 50% of its room temperature strength at 600oC). In the UK the most common way of dealing with fire is to protect the members provide insulation so that the steel temperature remains relatively low. Alternatively a fire engineering approach is possible, whereby the members are designed to resist the loads associated with the fire limit state with a reduced steel strength (as a function of the anticipated temperature).
The figure shows steel beams protected from fire by an off-site applied thin film intumescent coating.
Robustness
robustness of a building frame is defined as:
the ability of a structure to withstand events like fire, explosions, impact or the consequences of human error, without being damaged to an extent disproportionate to the original cause.
This requirement to design and construct a building to have robustness is established from BS EN [6]. Details of how the requirement should be met are given in BS EN -1-7[7] with practical guidance being provided by the Institution of Structural Engineers in their publication A practical guide to robustness and disproportionate collapse in buildings[8]. and SCI's P391 'Structural Robustness of Steel Framed Buildings'.
Acoustic performance
It may be necessary to consider the acoustic performance of the floor and walls, against both impact and airborne sound. This is particularly important for residential, school and hospital buildings. Sound insulation for both direct and flanking (at junctions) sound is controlled by the following three characteristics:
This means that the construction details of the floors, walls and their junctions in a building are the key to its acoustic performance. Floating floors and suspended ceilings should be considered it is not simply a question of adding mass.
In unusual cases there may be other checks to consider, for instance those considering the impact of thermal effects on the frame.
References
Structural design the engineers role, September , The Institution of Structural Engineers
BS EN -1-1: Eurocode 1. Actions on structures. General actions. Densities, self-weight, imposed loads for buildings, BSI
British Council for Offices Guide to Specification, , BCO
BS EN -1-1:+A1:, Eurocode 3: Design of steel structures. General rules and rules for buildings, BSI
BS EN -1-1: Eurocode 4. Design of composite steel and concrete structures. General rules and rules for buildings. BSI
BS EN :+A1:. Eurocode: Basis of structural design. BSI
BS EN -1-7:+A1:. Eurocode 1: Actions on structures. General actions. Accidental actions. BSI
Practical guide to structural robustness and disproportionate collapse in buildings, October . The Institution of Structural Engineers
Further reading
Resources
See Also
CPD
Pre-Engineered steel structures are truly popular in the commercial as well as industrial areas as a result of the client-related benefits that they provide consisting of the capacity to offer column-free flooring durations, blood circulation room, quicker as well as reputable building treatment. Also the budget friendly advantages they offer by being recyclable is another factor for popularity. A multi fabled PEB is an added benefit as one can achieve precise very same results at a much lowered cost and also create a much desired ROI in document time. In this post we will check out couple of benefits of building a multi-storied Pre-Engineered steel framework.
1. Much shorter timeline of construction
Pre-Engineered steel structure jobs merely call for producing on the structure as well as structure and also building and construction website with all the different other task finished in the production unit. As a result they are finished in a brief period which ensures a high price Rates of interest (ROI). The precise identical task that can take around a year to be finished in civil construction can get over within 7 to 8 months if one go with a Pre-Engineered structure.
2. PEB offers a column-free clear span design
The period width in PEB structures is added which recommends they utilize a better area. The piece dimension in PEB is moreover marginal than that in civil structures along with furthermore hence they on top of that offer a lot more utilizable area in terms of height.
3. PEBs can have concrete-like wall covering
For a concrete-like appearance from the outside one can make use of ACC blocks which are light-weight and also additionally can be set up on the wall surface areas with the steel columns or rafters of the Pre-Engineered frameworks. They not simply utilize the developing a civil framework surface area from outdoors which raises its aesthetic worth nonetheless additionally makes the structure and building treatment much faster in addition to lighter.
4. Steel structures come with an Eco-friendly structure certificate
Steel buildings are thought about Eco-friendly buildings as steel is 100% recyclable without the loss of premium. This top-notch of having the capacity to be recycled a number of times makes PEB frameworks really environment-friendly along with financially gratifying. Whenever we choose the construction of a Pre-Engineered steel framework we obtain an Environment-friendly building certification. This makes them not simply valuable for nature however on top of that offers us an advantage in connection with marketing.
5. PEBs are excellent financial investments
Pre-Engineered Frameworks are a great kind of financial investment for the future. Additionally, steel scrap can be converted into high-value steels by utilizing ideal methods of handling. Likewise thirty or forty years down the line if we pick to quit capitalizing on a PEB and additionally dismantle it, the entire structure will have fantastic scrap well worth and also likewise will definitely assist us to get a large amount of our preliminary financial investment. We can recover nearly 60% of our economic financial investment additionally on dismantling our PEB framework. Whereas, in civil structure frameworks we are turned over to no setup to redeem our financial investment if we make a decision to discontinue utilizing the structure or dismantle it.
6. Pre-Engineered frameworks are very easy to be taken down and also rebuilt
PEB frameworks are developed on the structure and also structure site with the help of nuts in addition to screws and additionally because of this they are very simple to uncouple in addition to tip. If for any kind of sort of sort of variable we select to relocate the steel PEB to one more website it can easily be done as the parts are light-weight in addition to problem-free to remove.
EPACK Prefab is among the fastest growing pre engineered building makers in India. With over two decades of producing experience, we have actually covered numerous square feet location with prefabrication.
If you are looking for more details, kindly visit Multi-storey Steel Structure Building.