FireLite® IGU – Fire-Rated, Fire/Impact Safety-Rated Insulated ...

Author: Ingrid

Aug. 26, 2024

21

0

0

Tags: Electronic Components & Supplies

FireLite® IGU – Fire-Rated, Fire/Impact Safety-Rated Insulated ...

TGP glazing can be used in any approved fire-rated door and frame assemblies.

Xieyuan Electronic Product Page

The polished surface quality is comparable to alternative fire-rated ceramics that are marketed as having a premium finish.

Both surfaces are ground and polished to provide superior surface quality, improving the overall clarity. FireLite Premium is the industry leader for quality and is unmatched by alternative products or production methods.

FireLite is made from transparent glass-ceramic which appears to have a warmer earth tone when compared to the blue green tint of typical float glass. Like float glass, FireLite ceramic will not demonstrate a highly perceptible color once installed in a frame. FireLite also features ultraHD® Technology, for improved color, clarity and surface quality. See the ultraHD® difference. View the available surface grades below or see our Premium FireLite FAQ for more information. These surface options are best reviewed prior to specification. Please contact TGP to request a sample kit.

Classified and labeled by Underwriters Laboratories, Inc.® and Underwriters Laboratories of Canada. File number for labeled fire-rated assemblies is R . Tests performed in accordance with:

"It&#;s very easy to be different, but very difficult to be better. "

FireLite IGU is composed of FireLite glass ceramic products and tempered or annealed float glass. Make-ups that achieve 3-hour fire ratings must be specified with FireLite NT or FireLite Plus®.

The time, in minutes or hours, that materials or assemblies can be expected to prevent flames and smoke from spreading.

As heat develops within the source area, pressure within the enclosed room begins to build relative to the pressure outside. Once the fire reaches equilibrium in the positive pressure zone, smoke, hot gases and flames are forced through any openings in the door or window assembly. Testing to the UL 10C standard more closely simulates real fire conditions.

Blocks radiant and conductive heat transfer from one side of the glass to the other. A required characteristic of glass used as a wall.

Classified and labeled by Underwriters Laboratories, Inc.® (UL), an independent product safety certification organization.

Immediately following a furnace test, heated glass is subjected to water from a fire hose. The cooling, impact and erosion created by the hose stream tests the integrity of the glass. In the U.S., the hose stream test is required for all fire ratings over 45 minutes (all fire ratings require it in Canada).

Available as a temperature rise door with Pilkington Pyrostop® fire-resistive-rated glass for 60-90 minute applications

Temperature rise doors provide a barrier to radiant and conductive heat transfer.

If you are looking for more details, kindly visit glass glaze resistor.

Available in stainless steel frame finish options for increased design flexibility.

Building codes clearly define hazardous locations where impact safety glass is required. Glass with this designation has been tested to meet impact safety requirements required for areas such as doors, sidelights, and areas close to the floor.

FireLite IGU is a fire-rated insulated glass ceramic unit that also complies with energy codes. It is designed for use in exterior applications where energy codes require an insulated product, or for interior applications with special needs such as sound reduction.

Withstands continuous temperatures to ° F for use in high efficiency heating appliances.

The ability of glass ceramic to withstand sudden heating, cooling, or both without cracking, shattering or exploding out of the frame.

The ability of the glass to stop various types of ammunition. Ratings are assigned in levels from 1 to 8, with a Level 8 rating being the highest (able to stop a 7.62mm rifle lead core full metal copper jacket, military ball).

The capacity of an element in a building structure to support a weight in addition to its own.

Listed and labeled by Intertek, an independent assurance, testing, inspection and certification organization.

Glazing designed to increase the amount of time required to gain entry. This additional time is intended to allow for the enactment of lock-down protocols and to allow for the arrival of emergency response teams. May be used in areas with high risk of prolonged attack or in critical areas such as vestibules. Forced entry resistant glazing should also resist penetration from hand-held or hand-thrown objects such as hammers, crowbars, bats, knives, bricks and rocks. (Source: NGA Glass Technical Paper FB71-21)

This product is both fire- and security-rated and is appropriate for educational facilities.

This product is smoke-rated and tested to UL .

Window Types and Technologies

In most windows the most important decision regarding energy efficiency is the selection of the glazing. Based on various window design factors such as window orientation, climate, building design, etc., you may even want to choose different types of glazing for different windows throughout your home.

For more detailed information about glazing options visit the Efficient Windows Collaborative to learn about the specific properties and efficiency of different glazing options.

While single glazing is common in older buildings, virtually all new efficient buildings use double or triple glazing units.  The "insulating glazing units", or IGUS, are available in a wide range of properties based on the type of glass selected, the coatings on the glass, the gas used to fill the space between the panes, and the spacers that keep the glazing separated. Below are some of the most common coatings and technologies you may find when shopping for windows:

Are you interested in learning more about metal oxide film resistor? Contact us today to secure an expert consultation!

Comments

Please Join Us to post.

0

0/2000

Guest Posts

If you are interested in sending in a Guest Blogger Submission,welcome to write for us.

Your Name: (required)

Your Email: (required)

Subject:

Your Message: (required)

0/2000